可编程直流电源、PV模拟电源
克 重:
TS Series
规 格:
-
单 价:
0.00 元/台
起 订:
1 台
供货总量: 0
发货期限: 自买家付款之日起 30天内发货
所在地: 上海市
有效期至: 2012年09月23日
最后更新:2012年08月24日
我要询价
公司基本资料信息
-
- 联系人 陈芸雁 ( 女士 )
- 会员 [加为商友] [发送信件]
- 邮件
- 电话
- 手机 13671590819
- 地区
- 地址
产品详情
Key Features
- Very high power density:
Up to 15 kW in a 3U package
- Wide voltage and current range:
Models up to 0-4000 Vdc and 0-2700 Adc
- Load dependent air cooling:
Variable speed fans on all models
- Wide range of input voltages:
From 208 Vac to 480 Vac, 50 Hz to 400 Hz
- Front panel analog potentiometers:
Stepless rotary control
- 37-pin optically isolated user I/O:
No additional circuitry necessary
- RS-232 interface standard:
Optional IEEE 488.2 GPIB, USB, LXI TCP/IP Ethernet, RS-485 interfaces
- CE Mark
- Made in the USA
Specifications
Input
|
Nominal Voltage
3 phase, 3 wire + ground |
208 VAC (operating range 187 - 229 VAC)
240 VAC (operating range 216 - 264 VAC)
380 VAC (operating range 342 - 418 VAC)
415 VAC (operating range 373 - 456 VAC)
440 VAC (operating range 396 - 484 VAC)
480 VAC (operating range 432 - 528 VAC) |
1 phase, 2 wire + ground |
208 VAC (operating range 187 - 229 VAC)
240 VAC (operating range 216 - 264 VAC) |
Frequency |
50 through 400 Hz |
Power Factor |
Greater than 92% at maximum power for 3 phase models,
Greater than 70% at maximum power for 1 phase models. |
|
Environmental
|
Operating Temperature |
0°C to 50°C |
Storage Temperature |
-25°C to +85°C |
Ambient Temperature |
0 to 50°C |
Temperature Coefficient |
0.04%/°C of maximum output voltage,
0.06%/°C of maximum output current. |
Air Cooling (Standard) |
Side air inlet, rear exhaust |
Water Cooling (Optional) |
25°C maximum inlet temperature
1.5 GPM minimum flow rate for 15 kW units
3.0 GPM minimum flow rate for 20-30 kW units
4.5 GPM minimum flow rate for 45 kW units
80 PSI maximum pressure
1/4” NPT female pipe size |
|
Physical
|
Power |
Input Phases |
Size (H" x D" x W") |
Rack Units |
Weight |
5 kW
10 kW
15 kW |
1?
1?
1? |
5¼" x 24" x 19" (13.34 x 60.96 x 48.26 cm)
10½" x 24" x 19" (26.67 x 60.96 x 48.26 cm)
15¾" x 24" x 19" (40.01 x 60.96 x 48.26 cm) |
3U
6U
9U |
75 lbs (34.02 kg)
150 lbs (68.04 kg)
225 lbs (102.06 kg) |
5 kW
10 kW
15 kW
20 kW
25 kW
30 kW
45 kW |
3?
3?
3?
3?
3?
3?
3? |
5¼" x 24" x 19" (13.34 x 60.96 x 48.26 cm)
5¼" x 24" x 19" (13.34 x 60.96 x 48.26 cm)
5¼" x 24" x 19" (13.34 x 60.96 x 48.26 cm)
10½" x 24" x 19" (26.67 x 60.96 x 48.26 cm)
10½" x 24" x 19" (26.67 x 60.96 x 48.26 cm)
10½" x 24" x 19" (26.67 x 60.96 x 48.26 cm)
15¾" x 24" x 19" (40.01 x 60.96 x 48.26 cm) |
3U
3U
3U
6U
6U
6U
9U |
74 lbs (34.57 kg)
94 lbs (42.64 kg)
125 lbs (56.70 kg)
195 lbs (88.45 kg)
220 lbs (99.79 kg)
245 lbs (111.13 kg)
365 lbs (165.56 kg) |
|
Output
|
Ripple |
See Model Charts |
Line Regulation |
Voltage Mode: ± 0.004% of full scale
Current Mode: ± 0.02% of full scale |
Load Regulation |
Voltage Mode: ± 0.01% of full scale
Current Mode: ± 0.04% of full scale |
Load Transient Response |
2 ms to recover within ±1% of regulated output with a 50% to 100% or 100% to 50% step load change |
Efficiency |
≥ 86%; See Model Charts |
Stability |
± 0.10% for 8 hrs. after 30 min. warmup |
Isolation |
Maximum input voltage to ground: ±2500 Vac
Maximum output voltage to ground:
±1000 Vdc for models less than or equal to 1000 Vdc,
±(2000 Vdc + Vo/2) for models greater than 1000 Vdc where Vo is the maximum output voltage of the power supply.
User inputs and outputs: referenced to earth ground.
|
Maximum Slew Rate |
Standard Models:
100 ms for an output voltage change from 0 to 63%,
100 ms for an output current change from 0 to 63%.
With High-Slew Rate Option
4 ms for an output voltage change from 0 to 63%,
8 ms for an output current change from 0 to 63%.
|
Bandwidth |
Standard Models:
3 Hz with remote analog voltage programming,
2 Hz with remote analog current programming.
With High Slew Rate Option:
60 Hz with remote analog voltage programming,
45 Hz with remote analog current programming.
|
Analog Output Impedances |
Voltage output monitoring: 100 ohm
Current output monitoring: 100 ohm
+10V Ref: 1 ohm |
|
Programming Levels and Accuracy of Full Scale
|
|
Voltage
Set Point |
Current
Set Point |
OVT
Set Point |
OCT
Set Point |
Remote Analog Programming Accuracy |
± 0.50% |
± 0.75% |
± 0.50% |
± 0.75% |
Digital Programming Accuracy |
± 0.50% |
± 0.75% |
± 0.50% |
± 0.75% |
Remote Analog Programming Levels |
0 - 10.0 Vdc |
0 - 10.0 Vdc |
0 - 10.0 Vdc |
0 - 10.0 Vdc |
|
Monitoring Levels and Accuracy of Full Scale
|
|
Output Voltage |
Output Current |
Remote Analog Monitoring Accuracy |
± 0.50% |
± 0.75% |
Digital Monitoring Accuracy |
± 0.50% |
± 0.75% |
Remote Analog Monitoring Levels |
0 - 10.0 V |
0 - 10.0 V |
|
Control Limits
|
Remote Sense Limits |
3% maximum voltage drop from output terminals to load. Remote sense is not available for models with output voltages greater than 1000 Vdc. |
Period Programming Limits |
Minimum period: 10 msec
Maximum Period: 9997 sec or 2.77 hours |
Digital control inputs and outputs limits |
Input voltage: 0 to 5 Vdc, 10K input impedance;
Output voltage: 0 to 5 Vdc, 5 mA drive capacity
5 V supply: 25 mA. |
打电话给我时,请一定说明在中纸在线网看到的,谢谢!
本企业其他产品
可编程直流电源、PV
可编程直流电源、PV
可编程直流电源、PV